DATA DIODE- DTD001 Cyb
Cybersecurity TCMS – Railway Systems

DataDiode - DTD

DataDiode DTD: Advanced Cybersecurity Solution for Secure Railway Communications

The DataDiode DTD from Leroy Automation is a cutting-edge railway cybersecurity solution, specifically designed to ensure secure communications in railway environments, in compliance with the EN 50155 standard. This unidirectional device blocks all communication in one direction while allowing secure data transfer in the other.

Unidirectional Data Flow for Enhanced Security of Railway Systems

The DataDiode DTD operates on the principle of unidirectional data flow, offering optimal protection against cyber threats. It enables secure data transfer while blocking unwanted communications, thereby enhancing the security of sensitive railway systems.

Protection of Critical Railway Infrastructure and Ensuring Data Integrity

Ideal for critical equipment such as remote diagnostic solutions, legal event recorders, and security information management systems (SIEM), the DataDiode DTD effectively protects railway infrastructures against intrusions. Acting as a physical barrier against cyber threats, it ensures data integrity and supports the continuity of railway operations while meeting the strict cybersecurity requirements of the railway sector.

MAIN FEATURES OF DATADIODE

  • EN 50155:2021 fully compliant
  • Hardware guaranteed unidirectional traffic
  • Protocol break technology
  • 2x 100Mbits/s independent and isolated channels
  • Low-latency transfer (250µs)
  • ARP on each Ethernet interface
  • Operating temperature : -40°C to +70°C
  • Full range power supply : 24Vdc to 110Vdc
  • 2x independent password protected maintenance ports
  • Dedicated network diagnosis LEDs on each Ethernet port

MECHANICAL INTEGRATION OF DATADIODE

  • Size-1U – half 19’’ rack-mount solution
  • Reduced weight (< 1Kg)
  • All communication ports available on front panel

TYPICAL APPLICATION OF DATADIODE

DATA DIODE

ENVIRONMENTAL QUALIFICATION TESTS OF DATADIODE

NF E 61000-4-2 2009 ESD Enclosure contact: ±6kV
Enclosure air: ±8kV
Criterion B
NF EN 61000-4-3 2020
Radiated immunity RFI
80MHz… 1GHz: 25V/m
1.4GHz… 2.1GHz: 15V/m
2.1GHz… 2.7GHz: 5V/m
5.1GHz… 6.0GHz: 3V/m
Criterion A
NF EN 61000-4-4 2013
Fast burst
±2kV direct/indirect
Criterion A
NF EN 61000-4-5 2014
Transient surge
±2kV MC
±1kV MD
Criterion B
NF EN 61000-4-6 2014
Conducted immunity RFI
150KHz…80MHz / 10Vrms
Criterion A
NF EN 55016-2-1 2014
Measuring conducted emissions
150kHz…500kHz
500kHz…30MHz
<99dBµV
<93dBµV
<50dBµV/m at 3m
NF EN 55016-2-3 2017
Measuring radiated emissions
230MHz…1GHz
1GHz…3GHz
3Ghz…6GHz
<57dBµV/m at 3m
<76dBµV/m at 3m
<80dBµV/m at 3m
NF EN 60068-2-1 2007 Cold storage -40°C 16 hours Criterion A
NF EN 60068-2-1
2007
Cold start
-40°C
Criterion A
NF EN 60068-2-2
2007
Dry heat
+70°C / +85°C 10min
Criterion A
NF EN 60068-2-30
2006
Damp test
+55°C 95% humidity 48 hours
Criterion A
NF EN 60068-2-14
2009
Fast temperature change
-25°C / +70°C / 5 cycles
Criterion A
NF EN 45545 2020 Railway applications /Fire protection on railway vehicles HL3
NF EN 60068-2-64 2008 Random vibration 5…150Hz – 1.01m/ s² Criterion A
NF EN 60068-2-64
2008
Simulated Long Life testing
5 … 150Hz – 7.9m/s² – XYZ 5 hours
Criterion A
NF EN 60068-2-27
2009
Shocks
50m/s² – XYZ – 30ms
Criterion A